Laparoscopy, also known as minimally invasive surgery or keyhole surgery, is a surgical procedure that allows surgeons to access the inside of the abdomen or pelvis using small incisions. It is performed using a laparoscope, which is a long, slender instrument with a light and camera attached to it.
During a laparoscopy, several small incisions, usually around half an inch to an inch in length, are made in the abdomen. Carbon dioxide gas is then pumped into the abdomen to create a working space and lift the abdominal wall away from the organs, providing better visibility for the surgeon.
Trocars: Trocars are used to create access points for the insertion of other instruments into the abdomen. They consist of a sharp, pointed tip and a sleeve that allows instruments to pass through while maintaining pneumoperitoneum (the presence of carbon dioxide gas in the abdominal cavity).
Technical Details:
Design :Flap | Pyramid | Size: Diameter 10.5mm,WL 100mm
Design :Flap | Pyramid | Size: Diameter 5.5mm,WL 100mm
Design :Flap | Pyramid | Size: Diameter 3.5mm,WL 100mm
Design :Flap | Safety | Size: Diameter 5.5mm|10.5mm,WL 100mm
Graspers: Graspers, also known as forceps, are used to grasp and manipulate tissues or organs during surgery. They come in various shapes and sizes, such as straight or curved jaws, and may have serrated or non-serrated surfaces to improve grip.
Scissors: Laparoscopic scissors have long, slender blades that allow cutting and dissecting of tissues. They are often equipped with a ratchet mechanism to provide better control and precise cutting.
Dissectors: Dissectors are used for separating tissues or adhesions during surgery. They have a blunt tip and a curved or angled shaft to facilitate dissection while minimizing trauma to surrounding structures.
Technical Details:
HANDLE| OUTER SHEATH| WORKING INSERT|ROTATABLE
Diameter :3mm|5mm|10mm WL:300mm|400mm
Standard Handle|Rachet Handle| Monopolar | Bipolar| Rachet Handle
Ergonomic | Light Weight
Needle Holders: Needle holders are specialized instruments used to hold and manipulate sutures during laparoscopic procedures. They have a locking mechanism that allows the surgeon to securely grasp and manipulate the needle.
Technical Details:
Diameter :3mm|5mm Length:260mm| 300mm|400mm
Pistol Needle Holder|Design: Right and Left Curved
Axial Needle Holder|Design: Straight,Self Aligning and Tooth Curved
V-Shape Needle Holder|Design: Right and Left Curved,Straight
Handle Material: Titanium | Stainless Steel | Light Wight
Suturing Devices: These instruments are designed to facilitate suturing during laparoscopic surgeries. They often have features like an articulating end, which allows for better maneuverability inside the body.
Technical Details:
Knot Pusher: Design: Full Circle | Half Circle | Conical Etc
Diameter : 3mm| 5mm Length:300mm
Scissor Type:Diameter : 2.1mm|2.5mm Length:110mm
Curved Nande Needle:Diameter : 2.1mm|2.5mm Length:110mm
Port closure Cone:Diameter : 5 mm|10 mm
Clip Appliers: Clip appliers are used to apply small clips or ligating devices to occlude blood vessels or ducts. These clips provide secure closure and help control bleeding during the procedure.
Technical Details:
Diameter : 5mm|10mm Length:300mm|400mm
Bipolar Instruments: Bipolar instruments are used for coagulation and cauterization during laparoscopic surgery. They utilize electrical energy to seal blood vessels and minimize bleeding. Bipolar instruments include bipolar forceps and bipolar scissors.
Technical Details:
Retrieval Bags: Retrieval bags are used to remove excised tissue or organs from the abdominal cavity. The tissue is placed in the bag, which is then closed and retrieved through one of the trocar sites, reducing the risk of contamination.
Technical Details:
Fan-shaped Retractors: These retractors have a fan-like design with adjustable blades that can be opened and locked in position. The blades are inserted between the liver and the abdominal wall, and then expanded to retract the liver gently.
Technical Details:
Diameter : 5mm|10mm Length:300mm|400mm
ARTICULATING CIRCULAR RETRACTORS | FAN TYPE
Technical Details:
Diameter : 3mm|5mm Length:300mm
MoPolar|BiPolar|UniPolar
Design: Button | Hook 90o | 45o